Analisis Efisiensi Sistem SCADA Dalam Monitoring Dan Data Logging Pada Plant Water for Injection (WFI) di Large Volume Parenteral (LVP) PT. Sanbe Farma

Main Article Content

Asep Najmurrokhman
Bunga Wahyudiani
Azmi Hafizat Muzada

Abstract

The Supervisory Control and Data Acquisition (SCADA) system is essential in pharmaceutical manufacturing, particularly for ensuring product quality and operational continuity in the Water for Injection (WFI) process at the Large Volume Parenteral (LVP) facility of PT Sanbe Farma. This study evaluates the efficiency and performance of SCADA in monitoring and logging WFI flow rate and conductivity. The assessment involves real-time data observation, historical trend analysis, efficiency measurement, and performance evaluation based on data availability, logging reliability, sampling frequency, event detection, and value consistency. Findings show that SCADA achieved 100% data availability for all monitored parameters, with a performance index consistently above 96%, indicating strong capability for real-time anomaly detection and uninterrupted data recording. Flow-rate monitoring efficiency reached 85% in May 2025 but declined to 70% in June 2025 due to process issues. In contrast, conductivity monitoring in both Cold and Hot loops remained highly efficient, exceeding 99%. Statistical results also revealed a 100% variability index and a high peak-to-average ratio, demonstrating the system’s accuracy in capturing dynamic fluctuations. Overall, the SCADA system in PT Sanbe Farma Unit 3 provides reliable monitoring performance and supports early disturbance detection, making it a strong basis for system maintenance and improvement.

Article Details

Section

Articles

How to Cite

Analisis Efisiensi Sistem SCADA Dalam Monitoring Dan Data Logging Pada Plant Water for Injection (WFI) di Large Volume Parenteral (LVP) PT. Sanbe Farma. (2026). EPSILON: Journal of Electrical Engineering and Information Technology, 23(2), 158-166. https://doi.org/10.55893/sxt4s992

References

[1] Z. Kılıç, “The importance of water and conscious use of water,” Int. J. Hydrol., vol. 4, no. 5, pp. 239–241, 2020, doi: 10.15406/ijh.2020.04.00250.
[2] A. Wutich, A. Y. Rosinger, A. Brewis, J. Stoler, and W. Jepson, “Measuring Human Water Needs,” Am. J. Hum. Biol., vol. 32, no. 1, pp. 1–17, 2020, doi: 10.1002/ajhb.23350.
[3] C. J. Perry, R. Allen, P. Droogers, A. Kilic, and R. Q. Grafton, “Water Consumption, Measurements and Sustainable Water Use,” Technical Report at The Global Commission on the Economics of Water, the Government of the Netherlands, 2023.
[4] N. M. Arwin et al., Air Minum untuk Kehidupan: Kualitas, Regulasi, dan Inovasi. Yayasan Kita Menulis, 2024.
[5] S. Ringa, “Sustainable water management in the pharmaceutical industry,” https://www.a3p.org/en/sustainable-water-management-in-the-pharmaceutical-industry/. (diakses tanggal 30 Agustus 2025).
[6] E. Strade, D. Kalnina, and J. Kulczycka, “Water efficiency and safe re-use of different grades of water - Topical issues for the pharmaceutical industry,” Water Resour. Ind., vol. 24, no. May, p. 100132, 2020, doi: 10.1016/j.wri.2020.100132.
[7] “Sistem Distilasi WFI: Standar Emas untuk Kemurnian Air Farmasi,” Shandong Eagle Pharma Machinery Co., Ltd (WEMAC), 2025. https://www.wemacpharma.com/id/WFI-Distillation-Systems-The-Gold-Standard-for-Pharmaceutical-Water-Purity (diakses tanggal 9 September 2025).
[8] “Water for Injection (WFI): Providing High Quality Pharmaceutical Water to Meet Industry Needs and Global Regulations,” Xylem, 2025. https://www.xylem.com/en-id/applications/water-for-injection-wfi/. (diakses tanggal 3 September 2025).
[9] D. F. Akbar, G. F. Tambunan, S. I. B. Siringoringo, R. N. Warnata, A. Irawan, and R. W. A. Rozak, “Implementasi Dan Perkembangan Sistem SCADA Di Industri : Tinjauan Dari Sudut Pandang Pakar,” J. Pengabdi. Masy. Pemberdayaan, Inov. dan Perubahan, vol. 3, no. 3, pp. 122–129, 2023.
[10] Ruwanto, D. Ridwan, A. A. Masriwilaga, H. Kabir, and D. Komaludin, “Implementasi Sistem Supervisory Control and Data Acquisition untuk Proses Koagulasi pada Instalasi Pengolahan Air Berbasis Programmable Logic Controller dan Human Machine Interface Supervisory Control and Data Acquisition System Implementation for The Coa,” TELEKONTRAN, vol. 11, no. 1, pp. 74–83, 2023.
[11] M. R. Abdilah, “Perancangan Sistem SCADA untuk Monitoring Kualitas Air Limbah dan Gas IPAL Komunal,” Skripsi Program Studi Teknik Elektro, Institut Teknologi Nasional Malang, 2023.
[12] A. Z. Manurung, M. Dwiyaniti, and N. Muhammad, “Kinerja Sistem Monitoring SCADA Pada PLANT Sistem Pendingin dan AHU,” Prosiding Seminar Nasional Terapan Riset Inovatif (SENTRINOV) Ke-11, 2025, vol. 11, no. 1, pp. 590–597.
[13] A. Mughaid, S. Alzu’bi, A. A. A. Alkhatib, A. AlZioud, A. Al Ghazo, and I. AL-Aiash, “Simulation-based framework for authenticating SCADA systems and cyber threat security in edge-based autonomous environments,” Simul. Model. Pract. Theory, vol. 140, no. April, p. 103078, 2025, doi: https://doi.org/10.1016/j.simpat.2025.103078.
[14] A. L. Sidiq, K. Dewi, B. J. Nugroho, and P. S. P. Pranida, “Integrasi Sistem IoT Berbasis Multi-Sensor Untuk Pemantauan Real-Time Kualitas Air Limbah Laboratorium Teknik,” J. Kumparan Fis., vol. 7, no. 3, pp. 106–113, 2024.
[15] R. K. Koppichetti, “Enterprise Data Lakes for Pharmaceutical Manufacturing : Enabling Digital Transformation in a Regulated Industry,” J. Adv. Dev. Res., vol. 14, no. 1, pp. 1–17, 2023.
[16] D. Quintana, L. C. Felix-herran, J. C. Tudon-martinez, and J. D. J. Lozoya-santos, “On Smart Water System Developments : A Systematic Review,” Water, vol. 17, p. 2571, 2025, doi: https://doi.org/10.3390/w17172571.
[17] S. Wang, Y. Vidal, and F. Pozo, “Recent advances in wind turbine condition monitoring using SCADA data : A,” Reliab. Eng. Syst. Saf., vol. 267, p. 111838, 2026, doi: 10.1016/j.ress.2025.111838.