Studi Rekonfigurasi Jaringan Distribusi 20 kV pada Penyulang DPRD ULP Cianjur Kota Menggunakan ETAP
Abstract
In the distribution of electricity from electric power sources to consumers who are located far apart, they always experience losses, namely in the form of voltage drops and power losses. However, the voltage loss that occurs in the process of distributing electrical energy is a waste of energy if it is not controlled optimally. Concerning the quality of service, the main factor which becomes the benchmark is the continuity of service and the quality of service voltage. The impact of these losses results in low levels of service quality to customers. Analysis of voltage drop and power loss is needed to determine the size of the voltage drop at the end of the DPRD feeder network. The calculation of voltage drops and power loss uses simulation results of ETAP method. The results of mathematical calculations and simulations are analyzed to determine the factors that cause the voltage quality at the end of the DPRD feeder network to be below the standard service voltage of 20 kV. The results of the analysis and simulation show that the factors that cause the voltage quality at the end of the DPRD feeder to be below the standard of service quality level are the transformer loading system, the type of conductor, and the distance of the substation to the far end of the feeder network. Then the problem was resolved by changing the type of conductor and reconfiguring it by shifting part of the load to the Lampegan feeder so that the voltage profile at the end of the DPRD Feeder was initially 17.527 kV after reconfiguration increased to 18.137 kV.
References
[2] G. A. Setia, G. H. M. Sianipar, and R. T. Paribo, “The performance comparison between fast decoupled and backward-forward sweep in solving distribution systems,” in 2016 3rd Conference on Power Engineering and Renewable Energy (ICPERE), 2016, pp. 247–251. doi: 10.1109/ICPERE.2016.7904871.
[3] G. A. Setia, G. H. M. Sianipar, K. Samudra, F. Haz, N. Winanti, and H. R. Iskandar, “Implementation of backward-forward sweep method on load model variation of distribution systems,” in 2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS), IEEE, 2019, pp. 1–5.
[4] A. A. N. Narottama, I. G. Agung, M. Sunaya, and I. M. Purbhawa, “Analisis Pengaruh Rekonfigurasi Jaringan Terhadap Pembebanan Transformator Pada Gardu Distribusi Ka 1316 Penyulang Sriwijaya,” vol. 4, no. 3, pp. 125–130, 2014.
[5] A. Tanjung, “Rekonfigurasi Sistem Distribusi 20 Kv Gardu Induk Teluk Lembu Dan Pltmg Langgam Power Untuk Mengurangi Rugi Daya Dan Drop Tegangan,” vol. 11, no. 2, pp. 160–166, 2014.
[6] V. Farahani, B. Vahidi, and H. A. Abyaneh, “Reconfiguration and Capacitor Placement Simultaneously for Energy Loss Reduction Based on an Improved Reconfiguration Method,” IEEE Trans. Power Syst., vol. 27, no. 2, pp. 587–595, 2012, doi: 10.1109/TPWRS.2011.2167688.
[7] PT. PLN, “Standar-Standar Tegangan,” Standar Perusah. List. Negara, p. 5, 1995.
[8] D. D. Yanuarta et al., “Rekonfigurasi Jaringan Distribusi Daya Listrik Pada Penyulang Pakusari Untuk Mengurangi Rugi-Rugi Daya,” Berk. Sainstek, vol. III, no. 1, pp. 6–10, 2015.
[9] G. A. Setia, F. Haz, and G. H. M. Sianipar, “Performa Metode Aliran Daya Fast Decoupled di Jaringan Distribusi,” vol. 3, no. 2, pp. 249–254, 2018, doi: 10.31544/jtera.v3.i2.2018.249-254.
[10] H. Nurohmah, A. Raikhani, and M. Ali, “Rekonfigurasi Jaringan Distribusi Radial Menggunakan Modified Firefly Algorithms (MFA) Pada Penyulang Tanjung Rayon Jombang,” JEEE-U (Journal Electr. Electron. Eng., vol. 1, no. 2, pp. 45–48, 2017, doi: 10.21070/jeee-u.v1i2.1064.
[11] H. Torang and Firdaus, “Analisa Rekonfigurasi Pada Feeder Sibuak Untuk Mengurangi Rugi-rugiI Daya dan Drop Tegangan Dengan Menggunakan ETAP 12.6.0,” vol. 4, no. 1, pp. 1–11, 2017.
[12] J. J. Grainer and W. Stevenson, Power System Analysis. McGraw-Hill Education (India), 1994. [Online]. Available: http://medcontent.metapress.com/index/A65RM03P4874243N.pdf
[13] B. Isnanto, M. Jumnahdi, and M. Y. Puriza, “Di Penyulang Dendang Pln Up3 Belitung,” 2019.
[14] K. Naim, “Analisa Rugi Daya Dan Jatuh Tegangan Pada Sistem Distribusi Tegangan Rendah Area Btn Hamzy Dan Btn Antara,” J. Teknol. Elekterika, vol. 13, no. 2, p. 136, 2016, doi: 10.31963/elekterika.v13i2.981.
[15] H. Prasetijo, “Rekonfigurasi Jaringan 20 kV untuk Perbaikan Profil Tegangan dan Susut Daya Listrik,” Techno, vol. 11, no. 2, pp. 56–63, 2010.