Studi Sistem Pentanahan Pada Transformator Daya 60 MVA di GIS 150 KV

  • Samsurizal Samsurizal Institut Teknologi PLN
  • Kathelya Nindya Ulina Institut Teknologi PLN
  • Andi Makkulau Institut Teknologi PLN
  • Nurmiati Pasra Institut Teknologi PLN
Keywords: NGR, GFR, single phase to short circuit current, TMS

Abstract

Grounding system is one way to reduce the effect of an electric current that can occur by several kinds of causes, such as leakage current or short circuit and the result of lightning surges. One method of grounding on a power transformer used by GIS Jatiwaringin is to use a NGR (Neutral Grounding Resistor) mounted on the 20 kV side, while on the 150 kV side it uses direct grounding (solid grounding) and the presence of a Ground Fault Relay. The value of single-phase short circuit current to the ground with resistance R = 12 Ω at the location with the percentage of disturbance of 25% that is equal to 928.48 Ω. Meanwhile, the value of single-phase short-circuit current to the ground without passing R at the location with a disturbance percentage of 25% is equal to 4066.55 Ω. Thus, the effect of the NGR on a single-phase to short-circuit fault current is to limit the one-phase short-circuit fault current to the ground so it does not flow to the neutral point of the transformer. The TMS value on the GFR on the outgoing side based on calculations is 0.11 and based on the installed relay is 0.12. Meanwhile, the TMS value on the GFR on the incoming side based on calculations is 0.27 and based on the installed relay is 0.15. Then, at the location with 25% disturbance percentage is 0.382 s. The difference between the relay's working time on the outgoing side and the incoming side is still in accordance with applicable standards, with a maximum difference of 0.4 seconds.

References

[1] A. Khurniawan, Sistem Pentanahan Switchyard Transformator 20KV/150KV Di PLTU Tanjung Awar-Awar, Jakarta: Sekolah Tinggi Teknik-PLN, 2015.
[2] M. Ir.Wahyudi Sarimun N., Proteksi Sistem Distribusi Tenaga Listrik, Depok: Garamond, 2016.
[3] I. G. D. A. I. W. R. I Gusti Agung Putra Sanjaya, “Analisis Setting Pengaman Transformator Daya Di Gardu Induk Nusa Dua Jika Terjadi Gangguan Hubung Singkat Satu Phasa Tanah,” E-Journal Spektrum Vol.4, pp. 28-31, 2017.
[4] A. U. Hutapea, Kajian Perancangan Sistem Pembumian Untuk Memenuhi Tegangan Sentuh dan Tegangan Langkah Di GISTET 500 KV Duri Kosambi, Jakarta: Sekolah Tinggi Teknik-PLN, 2019.
[5] P. R. Ariawan, Transformator, Jimbaran-Bali: Fakultas Teknik Universitas Udayana, 2010.
[6] N. Pamudji, Pedoman Trafo Tenaga, Jakarta: PT.PLN (Persero), 2014.
[7] R. T. Samalo, Analisis Sistem Pentanahan Pada Transformator Daya 60 MVA di GI Duri Kosambi, Jakarta: Sekolah Tinggi Teknik-PLN, 2017.
[8] A. S. Dewangga, Studi Koordinasi Proteksi Rele Arus Lebih, Diferensial dan Ground Fault Pada PT. Linde Indonesia, Cilegon, Surabaya: Institut Teknologi Sepuluh Nopember, 2015.
[9] T. S. T. O. Moh.Madani, “Analisa Setting Over Current Relay (OCR) dn Ground Fault Relay (GFR) Pada Trafo 60 MVA di GIS 150 KV Simpang,” Seminar Nasional Sains dan Teknologi Terapan VII 2019, pp. 685-686, 2019.
[10] A. Z. A. Rahman, Tinjauan Tekno Ekonomi Perhitungan Arus Gangguan Hubung Singkat Ke Tanah Berkaitan Dengan Nilai Neutral Grounding Resistor Untuk Penyetelan Ground Fault Relay, Jakarta: Sekolah Tinggi Teknik-PLN, 2018.
[11] S. A. B. Dedi Mirza, “Analisa Pengaruh Neutral Ground Resistant (NGR) 40 Ohm Pada Transformator Daya 30 MVA Di Gardu Induk Bireuen Terhadap Arus Gangguan Satu Fasa Ke Tanah,” Jurnal Energi Elektrik Volume 7, 2018.
[12] I. A. A. I Kadek Arya Surya, “Studi Pengaruh Pemasangan NGR 40 Ohm Pada Uprating Transformator 2 GI Gianyar Terhadap Gangguan Hubung Singkat 1 Phasa Tanah,” Teknologi Elektro, 2017.
[13] M. D. Kuncahyo, Analisis Setting Ground Fault Relay (GFR) Terhadap Sistem Pentanahan Netral Transformator Menggunakan Metode Neutral Grounding Resistor (NGR) pada Penyulang PLN Rayon Kuala Pembuang Kalimantan Tengah, Malang: Institut Teknologi Nasional Malang, 2017.
[14] PT.PLN (Persero), Pedoman Supervisi Kontruksi Jaringan, Transmisi dan Gardu Induk, Jakarta: PT.PLN (Persero).
[15] PT. PLN. (Persero), Proteksi dan Kontrol Transformator, Jakarta: PT.PLN (Persero).
[16] Samsurizal, Dedi.K, “Penyetinggan Loss Of Field Relay Proteksi Generator Pada Pembangkit Listrik Tenaga Air,” Setrum, 2019.
Published
2021-07-23