Abstract

Power transmission protection is a system that serves as a safety in the electrical equipment of a transmission network so that the process of channeling electrical energy to the consumer can run well. The power transmission system of the generating system can be through Extra High Voltage Overhead Line, High Voltage Overhead Line, and High Voltage Underground Cable. In each transmission line is required protection system that can protect the electricity distribution process to the consumer. High voltage underground cable is a transmission system that delivers electrical energy through a cable that is buried in the ground. Although it is in the ground and protected by an excellent insulation system, but does not escape also from the occurrence of interference. In the land cable channel protection system is known as the Line Current Differential (LCD) which is a protection system that works under Kirchoff Law 1 by comparing incoming flows and exiting flows, with uptime instantaneously. This research made a simulation of such system, using Arduino Mega 2560 and be equipped with Internet of Things (IoT) monitoring using Blynk. The test result indicated that the system can work properly

Article Details

Section

Articles

How to Cite

Simulasi Pengaman Pada Saluran Kabel Tegangan Tinggi Berupa Line Current Differential (LCD) Berbasis Arduino Mega 2560 Dengan Tampilan Human Machine Interface dan Notifikasi Blynk. (2022). EPSILON: Journal of Electrical Engineering and Information Technology, 19(3), 79-84. https://doi.org/10.55893/epsilon.v19i3.73

References

[1] S. Rosa, “Sistem Proteksi Distribusi Tenaga Listrik,” Pembangkitan Energi List., 2016.
[2] H. Haskarya, M. Pujiantara, and A. Musthofa, “Koordinasi Proteksi Saluran Udara Tegangan Tinggi pada Gardu Induk Mliwang – Tuban Akibat Penambahan Penghantar Pltu Tanjung Awar-Awar,” J. Tek. ITS, 2017.
[3] A. Ameli, A. Hooshyar, E. F. El-Saadany, and A. M. Youssef, “An Intrusion Detection Method for Line Current Differential Relays,” IEEE Trans. Inf. Forensics Secur., 2020.
[4] A. Aichhorn, B. Etzlinger, A. Unterweger, R. Mayrhofer, and A. Springer, “Design, implementation, and evaluation of secure communication for line current differential protection systems over packet switched networks,” Int. J. Crit. Infrastruct. Prot., 2018.
[5] G. Sivanagaraju, S. Chakrabarti, and S. C. Srivastava, “Uncertainty in transmission line parameters: Estimation and impact on line current differential protection,” IEEE Trans. Instrum. Meas., 2014.
[6] O. Avendano, B. Kasztenny, H. J. Altuve, B. Le, and N. Fischer, “Tutorial on Fault Locating Embedded in Line Current Differential Relays – Methods , Implementation , and Application Considerations,” Annu. West. Prot. Relay Conf., 2014.
[7] R. Berlianti and F. Fibriyanti, “Perancangan Alat Pengontrolan Beban Listrik Satu Phasa Jarak Jauh Menggunakan Aplikasi Blynk Berbasis Arduino Mega,” SainETIn, 2020.