ANALISA PERUBAHAN PEMBEBANAN TERHADAP ARUS EXITASI UNIT 1 PADA PT PLN (PERSERO) SEKTOR PEMBANGKITAN TELUK SIRIH

  • Sepannur Bandri Institut Teknologi Padang
  • Zuriman Anthony Institut Teknologi Padang
  • Rafika Andari Institut Teknologi Padang
Keywords: Arus Eksitasi. Generator Sinkron, Sistem Eksitasi

Abstract

Changes in the load of a generator are always changing according to the needs of community demand. On the generator side of the Teluk Sirih PLTU using charcoal brush media as a reinforcing field. Where excitation plays an important role providing DC current to the generator rotor to create an intersection of electromotive forces. Changes in generator load that are always changing can have an impact on damage to equipment such as generators, and excitation. Where on December 6, 2017 the excitation current reads low at 473.7 amperes directly proportional to the armature current of 1404.2 amperes, the resulting power will also be low at 13200000 watts and a frequency of 49.9 Hz, creating a magnetic flux of 0.125 Weber that is larger or feels heavy so that the generator rotation is low at 2999 rpm and vice versa. Therefore the role of excitation takes over in order to provide greater current so that the field strength is maintained stable. Increasing the excitation current (If) results in a greater induced electromotive force (Ea). This increase in Ea also impacts the terminal voltage (Vt), causing it to vary. This relationship demonstrates that higher excitation current leads to an increase in terminal voltage, which is essential for maintaining voltage stability. To stabilize the low terminal voltage resulting from load changes, it is necessary to amplify the field gain current. This can be achieved by increasing the excitation current on the synchronous generator rotor. Understanding the characteristics of the excitation system allows for minimizing and avoiding damage to the generator caused by both overexcitation and underexcitation, ensuring the maintenance of a stable terminal voltage.

References

[1] M. Farhan, “Pengaruh Pembebanan Terhadap Arus Eksitasi Generator Unit 2 Pltmh Curug,” J. Simetrik, vol. 11, no. 1, p. 398, 2021, doi: 10.31959/js.v11i1.653.
[2] S. Armansyah, “Pengaruh Penguatan Medan Generator Sinkron Terhadap Tegangan Terminal,” J. Tek. Elektro UISU, vol. 1, no. 3, pp. 48–55, 2016.
[3] D. R. Pattiapon, J. J. Rikumahu, and M. Jamlaay, “Penggunaan Motor Sinkron Tiga Phasa Tipe Salient Pole Sebagai Generator Sinkron,” J. Simetrik, vol. 9, no. 2, p. 197, 2019, doi: 10.31959/js.v9i2.386.
[4] Hamdan Rizal Maulana, Agus Suandi, and Helmizar, “Pengaruh Pembebanan Terhadap Arus Eksitasi Pada Generator,” Rekayasa Mek., vol. 6, no. 2, pp. 63–70, 2022, doi: 10.33369/rekayasamekanika.v6i2.25458.
[5] R. Tandioga, Marhatang, T. T. R. Payung, and H. Khatimah, “Analisis Pengaturan Tegangan Generator Sinkron Tiga Fasa Hubungan Bintang Akibat Pembebanan Tidak Seimbang,” Sinergi, no. 2, pp. 170–180, 2014.
[6] H. Herudin and W. D. Prasetyo, “Rancang Bangun Generator Sinkron 1 Fasa Magnet Permanen Kecepatan Rendah 750 RPM,” Setrum Sist. Kendali-Tenaga-elektronika-telekomunikasi-komputer, vol. 5, no. 1, p. 11, 2016, doi: 10.36055/setrum.v5i1.886.
[7] F. Sari and A. Darwanto, “Analisis Sistem Eksitasi Pada Generator Pararel Terhadap Daya Reaktif,” J. Teknol., vol. 14, no. 1, pp. 10–19, 2021, doi: 10.34151/jurtek.v14i1.3276.
[8] Yusniati and Matondang NNS, “Analisis sistem pembebanan pada generator di PT.PLN (persero) pembangkit listrik tenaga diesel titi kuning,” Semnastek Uisu , pp. 59–64, 2020.
[9] P. Dosen et al., “Karakteristik Generator Sinkron Yang,” vol. 2, pp. 115–120, 2017.
[10] R. Ricky and J. Windarta, “Analisis Komparasi Perhitungan Teori dan Aktual Terhadap Daya Aktif dan Daya Reaktif Steam Turbine Generator 2.0 Pada PT Indonesia Power Semarang,” J. Energi Baru dan Terbarukan, vol. 1, no. 1, pp. 8–19, 2020, doi: 10.14710/jebt.2020.8133.
[11] A. Annisa, W. Winarso, and W. Dwiono, “Analisis Pengaruh Perubahan Beban Terhadap Karakteristik Generator Sinkron,” J. Ris. Rekayasa Elektro, vol. 1, no. 1, pp. 37–53, 2019, doi: 10.30595/jrre.v1i1.4928.
[12] S. Bandri, “Pengaruh Analisa Beban Perubahan Karakteristik Terhadap Sinkron Generator,” Inst. Teknol. Padang, vol. 2, no. 1, pp. 42–48, 2013.
[13] M. Harahap, “Pengaruh Perubahan Variasi Eksitasi Tegangan Terhadap Daya Reaktif Pada Generator,” Univ. Prima Indones., vol. 3, no. 2, pp. 71–76, 2021.
[14] S. A. Putra and D. B. Santoso, “Analisis Pengaruh Arus Eksitasi Terhadap Daya Reaktif Generator Sinkron Unit 3 Plta Ubrug,” J. DISPROTEK, vol. 13, no. 2, pp. 113–122, 2022, doi: 10.34001/jdpt.v13i2.3160.
[15] U. Situmeang, “Analisis Pengaruh Perubahan Besaran,” vol. 1, no. 1, pp. 1–8, 2016.
Published
2023-08-10